500 kW liquid cooled load bank for data centre cooling validation

500 kW Liquid Cooled Load Bank for Data Centre

Designed for simultaneous commissioning of data centre power infrastructure and liquid cooling systems.

500 kW Liquid-Cooled Load Bank

View 500 kW Full Specifications →
500 kW liquid cooled load bank front view

01 — Overview

Liquid-Cooled Load Bank: Working Principle for Data Centre Cooling Validation

Designed for data centre liquid cooling validation, the liquid-cooled load bank applies pure resistive electrical load while simultaneously transferring heat into the liquid cooling circuit. One unit delivers both power testing and chiller performance validation.

Liquid Cooling Load Bank = Resistive Heating + Direct Liquid Cooling.
Simulates server power consumption for electrical testing, and precisely transfers heat into the liquid cooling loop for cooling system testing.
One machine completes power testing and cooling system testing simultaneously.

Liquid cooled load bank application diagram showing power and cooling circuits
Power Loading (Simulating IT Load) Equipped with pure resistive load elements, the load bank connects to UPS, generators, and PDUs to simulate real server power load, testing power capacity, voltage drop, stability, and protection logic.
Heat Generation & Direct Conduction Heat generated during resistive loading is not released into the air. Instead, it is transferred into thermal load via a 316 stainless steel heat exchanger for removal by the liquid cooling circuit.
Liquid Cooling Cycle (Simulating Heat Source for CDU/Chiller) Coolant (glycol, deionized water, or fluorinated fluid) circulates from the CDU/chiller through the load bank, removing heat and returning to form a closed, stable, measurable thermal cycle.
Control & Protection The control system adjusts load power in real time and monitors temperature, flow, and pressure, enabling synchronized, accurate testing of data centre power and cooling systems.

02 — How It Works

Liquid Cooled Load Bank — How It Works

1
Direct Cooling Tower Connection

This liquid-cooled load bank supports direct connection to most cooling towers, with adaptable interfaces for different site piping standards.

Designed specifically for cooling tower performance validation, it delivers efficient, direct thermal load testing for data centre liquid cooling projects.
2
Integrated Water Tank Design

Ensures consistent cooling performance and avoids thermal risks.

Closed-loop water circuit with no air pockets, no hotspots, no dead zones. Uniform flow distribution, stable controllable pressure, and no hydraulic shock.
3
Wireless Remote Control

Enables fast-track site commissioning without complex wiring.

PC cluster control software is available. An optional wireless communication module supports multi-load group control without dedicated network infrastructure.
4
Local PLC + Touchscreen Control

Guarantees reliable on-site operation even without network access.

On-site operation via local PLC controller and touchscreen HMI panel. Full manual control is available, with no network dependency during commissioning and testing.

03 — Full Range Customization Services

Liquid Cooled Load Bank Customization Services

Every unit is configured to your exact specification — from power rating and enclosure dimensions to connection interface and communication protocol.

Custom power rating configuration for liquid cooled load bank

Custom Power Rating

Configured to your exact power output from 50 kW to 500 kW and beyond — specify voltage, phase, and load step resolution.

Custom dimensions and mounting options for liquid cooled load bank

Custom Dimensions & Mounting

Cabinet footprint, enclosure height, and wheel / skid / trailer mounting options configured to fit your facility constraints.

Custom communication protocol integration for load bank control

Custom Protocol

Standard TCP/IP and Modbus RTU; custom communication protocols available to integrate with your test automation system.

Custom flanges and coolant connections for liquid cooled load bank

Custom Flanges & Connections

DN100 flanged (4") or DN50 quick-connect (2") as standard; custom flange sizes and connection types available to match your CDU circuit.

Custom power supply options for liquid cooled load bank

Custom Power Supply

Single-phase or three-phase input; custom voltage range and frequency to match local grid standards or generator output specification.

Complete test solution with accessories for liquid cooled load bank

Complete Test Solution

Full accessories package: manifold connectors, UPE flexible hoses, ball valves, flow meters, and quick-connect fittings for immediate deployment.


04 — Manufacturing

Liquid Cooled Load Bank Manufacturing & Testing

Every unit is assembled, tested, and inspected in our dedicated liquid-cooled load bank workshop before leaving the factory.

Batterlution large-scale liquid cooled load bank production facility

Large-Scale Production Facility

Dedicated liquid-cooled load bank manufacturing workshop — purpose-built for large-scale industrial assembly, testing, and quality verification of high-power units.

In-house cooling tower testing loop for load bank validation

Mature Cooling Tower Testing

In-house cooling tower loop available for pre-shipment validation. Every unit undergoes full-load testing before dispatch to verify on-site performance.

Software-based thermal simulation for liquid cooled load bank design

Software-Based Thermal Simulation

Reliable software simulation of water stratification and inlet/outlet temperature differentials — models heat dissipation behaviour to verify thermal performance before physical testing.

Safe export packaging and pre-shipment protocol for load bank delivery

Safe Export Packaging & Pre-Shipment Protocol

Every liquid-cooled load bank is nitrogen-purged and dried before shipment to prevent internal corrosion during transit. Secure export packaging ensures safe worldwide delivery.


05 — Software

Liquid Cooled Load Bank Intelligent Control Software

Intelligent control software dashboard for liquid cooled load bank
1
Wireless PC Cluster Control

Wireless centralized control for multiple load banks from one PC.

Achieve synchronous loading and unified management of parallel units, greatly improving efficiency for large-scale data centre commissioning.
2
Real-Time Parameter Monitoring

Real-time monitoring of all key test parameters.

View voltage, current, power, inlet/outlet water temperature, flow rate and pressure on one intuitive dashboard.
3
Test Log & Report Export

Automatic data logging and one-click professional report export.

Generate timestamped test records & standardised PDF/Excel reports for easy acceptance and compliance filing.
4
Customizable HMI & Logic

Custom interface and control logic to match your workflow.

Flexible customization of screen layout, test steps and alarm rules for site-specific applications.

06 — Applications

Liquid Cooled Load Bank Applications

1
Power System Load Test

Validate UPS, generator, and PDU performance before go-live.

Apply rated resistive load to test electrical performance and switchgear thermal behaviour, ensuring reliable operation before the IT hall goes live.
2
CDU & Chiller Validation

Verify CDU and chiller performance under full thermal load.

Apply thermal load to the CDU return line to test chiller sizing, flow balancing, temperature regulation, and alarm response.
3
Cooling Tower Circuit Commissioning

Stabilize your full heat rejection chain and identify bottlenecks.

Maintain stable thermal load across the tower, chiller, CDU, and load bank to detect issues before site commissioning.
4
ESS & Storage Integration

Simulate accurate charge/discharge cycles for liquid-cooled energy storage.

Programmable thermal load for battery or thermal storage systems, replicating real-world conditions during testing.
5
Partial Load Transfer Testing

Validate N+1 and 2N cooling redundancy with staged load steps.

Monitor switchover performance and thermal margin under partial load to confirm redundancy works as designed.

07 — The Process

Liquid Cooled Load Bank Ordering Process

  1. You Send the Spec Power, voltage, application, communication protocol. We confirm feasibility and issue a quotation within 48 hours.
  2. Unit Built to Your Spec Power, protocol, protection thresholds, and interface fittings — all configured and tested at the factory before dispatch.
  3. Delivery & Site Prep Unit arrives. You prepare coolant connections (DN100 or DN50) and electrical supply. Installation guidance provided.
  4. Commissioning On-site integration supported. Multiple units paralleled if required. Protection set-points aligned to your test plan.
  5. Test Run & Sign-off Engineer executes the validation sequence. Load applied, cooling chain responds, data logged, system signed off.

08-FAQ

FAQ

Can this unit test power systems and cooling systems at the same time?

Standard models support up to 5MW per container. Larger capacities are achieved through synchronised parallel operation of multiple cabinets — up to 30MW+ under unified control.

Standard voltages are 400V / 690V. Medium-voltage versions at 10.5kV and 13.8kV are available as custom configurations. All configurations are engineered to order.

Liquid-cooled and containerised are separate product lines. Batterlution’s liquid-cooled load banks are available in rack-mounted and floor-standing form factors.

A 20ft container typically accommodates 1–3MW of capacity. A 40ft container typically accommodates 3–5MW+. Choose based on your project power requirement and available site footprint. Custom sizes are available.

Yes. RS485 / Modbus RTU and Modbus TCP/IP are standard. Optional app-based remote control and unified parallel control across multiple cabinets are available.

Once the container is positioned and cables are connected, the system is ready for testing in approximately one hour. No civil engineering or equipment room required.

Send your power requirement, voltage, container size, and test scenario. We will confirm the configuration and issue a quotation within 48 hours. No obligation — custom configurations are welcome.